Repair of Necta Actuator Board Samba Top / Rock (ACT 6735-558-00)

Repair of Necta actuator board 6735-558-00 for Samba Top and Rock vending machines

Necta actuation card 6735-558-00

Photo of Necta Samba Top actuation board

The Necta actuator board (part number 6735-558-00) is the actuation (control) module primarily responsible for operating the product dispensing motors in Samba Top and Necta Rock models. Its failure is a very common cause of issues with product dispensing.

Necta machine models where this board is commonly found

  • Necta Samba Top
  • Necta Rock

Most common faults of Necta actuator board 6735-558-00

  • Incorrect motor control - spirals are not being detected, do not respond, etc.
  • Shelf/column not detected - the machine does not recognize the selected shelf or ignores an entire column

How to diagnose Necta actuator board 6735-558-00

  • check if the LED3 (power supply indicator) is lit on the board. If not - verify whether the board is receiving 24 V AC on the outermost pins of terminal J16. If there is no voltage – look for the cause in the machine (check fuses / wiring). If voltage is present but LED3 is off - the board is faulty.
  • check if the green LED1 (heartbeat) is blinking. It should be blinking regularly under normal operation.
  • check whether LED2 (RESET) lits or blinks. If it is permanently on or blinking constantly - the board has failed to boot - the board is defective.
  • if the board starts up but does not control the motors - check LED4 (door switch / safety enable). If LED4 is not lit - the board has detected that the machine door is open / door switch circuit is not closed → motor control is intentionally disabled for safety. Check or repair the door switch / door closing circuit. Once the circuit is closed properly, LED4 should light up (no need to restart the machine to see this change). After fixing the door issue → restart the machine.
    Both LED3  and LED4 should lit

    LED3 & LED4 location: they both have to lit while normal operation

Location of LED3 and LED4 – both should be illuminatedIf LED3 and LED4 are both on, but the board still does not drive the motors - this indicates a fault in the executive board itself.

Price and turnaround time

Price : 93 EUR net

Turnaround time : 5 working days

Description : Standard repair for most boards (CPU, actuator, hub board)

The quoted price and turnaround time are estimates. In rare, unusual cases, we will agree on the conditions with you beforehand.

How to prepare and send the board for repair

IMPORTANT: In this case, we require the complete set from you: the CPU board + the actuator board.

  1. Label the package
    Clearly write on the box: “ELECTRONICS FOR REPAIR - VENDFix.eu”

  2. Describe the faults
    Attach a note to each board with the problem description (defines diagnostic scope)

  3. Include invoicing and return shipping details

    • Company name / full name
    • Full address (including postal code and city)
    • VAT number (if company)
    • Phone number and email
  4. Send to:

    VENDFix
    Techniline sp. z o. o.
    Sosnowa 4
    26652 Janiszew
    Poland
    tel. +48 696-42-10-42

Ready to send your Necta 6735-558-00 actuator board?

Contact us